All Articles Heating

Why an Old Chimney Can Fail a New Boiler or Water Heater

An old building's mechanical room, a tall storage tank and a red circulator among galvanized and copper piping, valves and gauges in a wood framed cellar
A new wall standing boiler beside an indirect water heater tank, with copper near boiler piping, an air separator and a new expansion tank overhead
A New Boiler and an Indirect Water Heater

Two companies look at the same cellar. One quote includes a chimney liner and the other does not. The one without it is cheaper, and nothing in either document explains the difference.

This is the article that explains it, because the liner is usually not an upsell. It is often the condition on which the new appliance is allowed to vent at all.

What Does an Old Atmospheric Appliance Need From a Chimney?

Heat, and a chimney that is in proportion to it.

An atmospheric boiler or water heater has no fan pushing its exhaust. It relies on the exhaust being hot enough and buoyant enough to rise up the chimney on its own, pulling fresh combustion air in behind it. That is draft, and it is a physical effect rather than a mechanical one.

Draft needs the flue to stay warm. Flue gases that cool on the way up slow down, stop rising properly, and give up their moisture against the inside of the chimney. In a masonry chimney that moisture is the thing that destroys tile and mortar from the inside, and it is also the thing that makes a cold chimney refuse to draft at all on a windy morning.

That is why chimney size is not a case of bigger being safer. A chimney that is too large for what it carries is a chimney whose gases cool too much.

What Changes When One Appliance Comes Off and Another Stays?

The chimney stops being the right size, and nobody has moved a brick.

In a huge number of older houses around here, the gas boiler and the gas water heater share one masonry flue. The boiler is the big producer. It is what keeps the chimney warm, and the chimney was sized with both appliances on it.

Replace that boiler with a high efficiency unit that vents out through the wall, and the water heater is left on the chimney by itself. The trade calls that an orphaned water heater, and it is the most common version of this problem.

Nothing about the water heater has changed. What has changed is that a small appliance is now trying to drive a flue that used to be warmed by something several times its size. Cooler gases, weaker draft, and condensation where there was none before.

The failure mode is the one that matters most. An appliance that cannot establish draft can spill its combustion products into the room instead of up the chimney, which is a carbon monoxide question rather than a comfort one, and a water heater burns fuel all year rather than only in the heating season.

What Does Massachusetts Actually Require?

This is where the two quotes diverge, and the state has a specific provision on it.

Massachusetts amends the national fuel gas code, and its amendment to the venting chapter sets out when a tile lined chimney, or an existing chimney that does not meet the code’s requirements, may still be used with a replacement or new gas appliance, including a gas appliance replacing an oil one. Three conditions have to be met:

  • The existing appliance must have operated with a non positive vent static pressure that did not create condensation in the chimney.
  • Existing chimneys may not be utilized when replacing an atmospheric appliance with a fan assisted appliance.
  • An existing chimney may only be used with one or more gas appliances if the interior area of the chimney is no greater than seven times the area of the smallest flue to be connected to it.

Read the middle one again, because it does most of the work in a real job. A great many current gas boilers and furnaces are fan assisted, including units that are not fully condensing. Where the appliance coming out is atmospheric and the one going in is fan assisted, that clause answers the question on its own.

The first condition is the one that speaks to the orphaned water heater, because it asks what the chimney has actually been doing. A flue that has been condensing is not a flue the exception was written to permit.

The third is a sizing limit. It is also the reason a liner is the usual remedy rather than a rebuild: putting a correctly sized liner inside an oversized masonry chimney changes the interior area the appliance is venting into, without touching the structure.

Why Does One Quote Include a Liner and Another Does Not?

Usually for one of three reasons, and only one of them is about price.

The chimney was looked at and the other one was not. A quote written off the model number of the old boiler can be produced without anyone putting a light up the flue.

The two quotes are for different appliances. A fan assisted replacement and an atmospheric replacement are not in the same position under the rule above, so two honest companies can reach different answers about the same chimney.

It was left out to make the number smaller. It happens, and the thing to understand is that it does not stay left out. The work still has to satisfy the inspector, so a liner omitted at the quote stage becomes a change order at the install stage, in a week when the heat is off.

So the question worth asking is not which quote is cheaper. It is what each company found when they looked at the chimney, and what the plan is for the water heater once the boiler is no longer sharing the flue. Our boiler replacement page sets out what we assess before quoting, and the same question applies to a water heater replacement where the tank is the only thing left on the chimney.

What Does a Liner Actually Do?

It gives the appliance a flue sized for the appliance.

A liner is a continuous metal flue run down the inside of the masonry chimney and connected to the appliance at the bottom and terminated at the top. The exhaust travels inside the liner rather than against the brick and tile, which keeps it warmer, lets draft establish and keeps the moisture off the masonry.

It is also an insurance policy on the chimney itself. The reason old flues crumble at the top and shed tile into the smoke chamber is decades of condensation and acidic flue gas against the mortar, and a liner takes the exhaust out of contact with it.

It is worth saying plainly that the liner is for the appliance rather than for the chimney’s appearance. Nothing about it shows from the street.

Is Combustion Air Part of the Same Question?

Yes, and it is the half that gets forgotten.

An atmospheric appliance pulls its combustion air out of the room it stands in, and that air has to be replaced from somewhere. In an old, leaky cellar there was always enough. Then the house gets a new boiler, new windows, air sealing and a tighter basement, and the air that the water heater quietly relied on is no longer arriving.

A starved burner and an oversized flue are the same problem from two directions, and both end at the same place, which is a flue that does not draft and a burner that spills. Anyone assessing a chimney for an orphaned appliance should be looking at where its air comes from in the same visit.

The same logic runs the other way for the new unit. A high efficiency appliance that vents out through the wall usually brings its own combustion air in through a second pipe, which is why snow at a sidewall termination stops it rather than merely slowing it down.

Does Any of This Apply to a Steam Boiler?

The chimney question does, and the replacement question looks different.

A steam boiler is generally a larger, atmospheric appliance on a masonry flue, so it is normally the thing keeping the chimney warm rather than the thing being orphaned. Replace it and the same three conditions come into play for whatever is going on that flue next, including a water heater left behind.

What makes steam its own conversation is the rest of the system rather than the venting, and our steam boiler page covers that. If the underlying question is whether the boiler needs replacing at all, what actually ends a heating system is the better place to start.

Questions We Hear

Can the Water Heater Just Stay on the Chimney?

Sometimes, and it depends on what the chimney is and what is going on it. That is exactly the assessment the conditions above describe, and it is answered by looking at the flue and the appliances rather than by a general rule. What should not happen is the boiler coming out with nobody having asked the question.

Is a Liner Required Every Time a Boiler Is Replaced?

No. It is required when the existing chimney cannot satisfy the conditions for being used with the new appliance, which is a different thing from a blanket rule. The cases where it comes up most are a fan assisted unit replacing an atmospheric one, and an appliance left alone on a flue that was sized for more.

Could We Vent the Water Heater Out the Wall Too?

In some situations that is the cleaner answer, with an appliance built for it. What cannot happen is sending the exhaust of an appliance through pipe its own manufacturer does not permit. Massachusetts limits plastic venting to CPVC, polypropylene, and other pipes where the appliance manufacturer’s installation instructions explicitly allow them.

How Would I Know if My Chimney Is Already Suffering?

The tells are at both ends. At the top, crumbling mortar, a cracked crown or missing tile. At the bottom, rust and white staining on the appliance draft hood or vent connector, or debris in the base of the chimney. Any of those is worth a look before a replacement rather than after.

Does the Inspector Decide This or Does the Installer?

The installer has to do the work correctly and the inspector checks it, so in practice both. The useful consequence for a homeowner is that a liner left out to win a quote is not a saving that survives the inspection, and the licenses behind the work are checkable against the Commonwealth’s own register.

Something in Your Own Building Not Right?

Tell us what it is doing and we will tell you what it usually means. Call (617) 549-5734 or send it through the shop.

This article is general information about how gas appliances vent into masonry chimneys and what Massachusetts requires when an appliance is replaced. It is not an assessment of any particular chimney, which has to be looked at, and the provisions described here are the current state amendments to the fuel gas code rather than the whole of the venting rules.

More From the Work

Something Leaking? No Heat? Talk to the Shop.

Send over what is happening and when we can reach you.

What Do You Need?

(617) 549-5734

Casper works out of Quincy, and the trucks run Quincy, Dorchester, Weymouth, Braintree and Milton.

Tell Us What Is Going On

Can We Call You Back in the Next 10 Minutes?

Tell Us What Is Going On

Can We Call You Back in the Next 10 Minutes?